High performance heating cartidges SHLP
All SHLPs can be provided with thermocouple.
The compensating circuit will be manufactured to customer requirements.
Unless agreed otherwise, the thermocouple will be electrically isolated from the cartridge casing.

Connecting versions:
- Reduced glass-fiber isolated nickel strand
- Temperature resistant up to 400°C max.
- High-temperature nickel strand up to 700°C max.
- Teflon nickel strand up to 260°C max.
- Silicone strand up to 180°C max.
- Feed line length 1000mm
Additional protection:
- Glass-fiber tube
- Corrugated metal tube
- Metal braided sleeving
Mounting versions:
- Screw-in fitting
- Flange plates
Tolerances:
| Diameter: | -0.02mm to 0.08mm |
| Length: | +/-1.5%, or min. +/-2mm |
| Power: | +5/-10% |